Place of Origin: | USA |
Brand Name: | Dolphs |
Certification: | UL,SGS |
Model Number: | Dolphon®CB-1054 |
Dolphon®CB-1054polybutadiene casting resin
describe
is A kind of black, thixotropy, flexible polybutadiene casting resin.
performance
at room temperature curing, and curing shrinkage rate is very low.
In the humid environment also keep good electrical performance. In addition to having good flexibility, can also on a variety of surface adhesion.
The processing of the filling of liquid resin, will not be wear and tear. Has excellent abrasion resistance environment, such as dust or ice particles.
application
Dolphon®CB-1054 commonly used in motor, transformer, generator windings of casting potting, usually used in the motor and transformer under 130 ℃. Also can be used in the electronics field.
standard
Using temperature is 130 ℃
Accordance with the requirements of the RoHS - 2011/65 / EC.
Standard color is black.
Placing conditions
In a completely sealed original tank, in the storage temperature is not higher than 25 ° C, resin and curing agent can hold up to 12 months. Because of resin and curing agent on the sensitivity of the humidity, can deposit.
Method of use
If casting resin consumption faster, can join again in warm resin curing agent CB 1128 B. Other cases need to cool to room temperature, so not shorten the mixing time. A mixture, resin, curing agent and prepared to avoid be affected with damp be affected with damp. The temperature of the workshop can not less than 18 ° C.
Need to pay attention to, casting the workpiece surface is dry. Need to slowly heated to remove water (for example, 50 ℃) an hour, otherwise the resin in the curing process to form bubbles.
The addition of CB 1128 B need according to the regulation of mixed proportion. Gently stir until mixture evenly to avoid air bubbles. Preheat curing agent can be mixed to slightly easier.
The abrasive polybutadiene casting resin CB 1128 can be used in a vacuum or not in the ratio of mixing equipment and equipment of vacuum.
curing
Curing is the need to keep the environment relative humidity is low, especially when very thin coating. Needs to be done at room temperature, curing or slightly higher than the room temperature (about 40 ℃). Electronics and machinery of abrasive materials need at least 48 hours at room temperature (low temperature 20 ℃).
The work equipment clean
Because of the cured resin was actually insoluble, equipment and processing equipment needs in a timely manner with Voltatex ® 5050 clean.
Protection measures
No biological activity after curing of CB 1128, harmless to the human body. In dealing with a liquid resin using conventional protection measures: see dupont and ec safety data sheet and chemical industrial insurance association rules M 044.
Technical data
Numerical test method of unit conditions
The mechanical
Shaw hardness after D around 20 ℃ (45 + / - 5)
Numerical test method of unit conditions
electrical
Breakdown voltage kV/mm 23 ℃ 26 kV/mm according to IEC 60243-1-0.025 mm
Volume resistance 23 ℃ Ω * cm 23 ℃ acuity 1015 Ω forced the cm ASTM D - 257
Specific Volume to hold, at 20 ° C Ω * cm 25 ℃ or higher 1014 Ω forced the cm ASTM D - 257
Dielectric constant of 25 ℃ 50 Hz 3.3 ASTM D - 150
Loss coefficient of 25 ℃ 50 Hz or less 10-3 31 forced the ASTM D - 150
Unit value detection method
thermodynamics
Temperature index and 40 ° C / + 150 ° C Oliphant Test
Thermal conductivity is 0.42 W/(m forced the K) - 1
Glass transition temperature of 60 ℃ or less DSC
Unit value detection method
The liquid phase
Mix ratio of 100:6 weight - %
The mixture 80000/120000 mPa • s Brookfield viscosity 25 ℃
Tank for (+ 5) for 45 min 20 ℃ (100 g) sample
Gel time 15 min min 25 ℃
Curing time of 48 h/RT or 6 h/RT + 3 h / 80 ° C
The impact on the enameled wire is compatible with all common enameled wire
Mixture density (1.1 + 0.05) g/cm after
Volume contraction < 0.01%
3)